LEESON SM Series Sub-Micro Inverters User Manual
Page 30

26
14.0
PARAMETER MENU
FACTORY
NO.
PARAMETER NAME
RANGE OF ADJUSTMENT
DEFAULT
01
LINE VOLTAGE
HIGH (01), LOW (02)
HIGH (01)
02
CARRIER FREQUENCY
4kHz (01), 6kHz (02), 8kHz (08), 10 kHz (04)
6 kHz (02)
03
START METHOD
NORMAL (01), START ON POWER UP (02),
NORMAL (01)
START WITH DC BRAKE (03),
AUTO RESTART WITH DC BRAKE (04),
FLYING RESTART 1 (05,) FLYING RESTART 2 (06),
FLYING RESTART 3 (07)
04
STOP METHOD
COAST (01), COAST WITH DC BRAKE (02),
COAST (01)
RAMP (03), RAMP WITH DC BRAKE (04)
05
STANDARD SPEED
KEYPAD (01), PRESET #1 (02),
KEYPAD (01)
SOURCE
0-10 VDC (03), 4-20 mA (04)
06
RELAY OUTPUT
NONE (01), RUN (02) ,FAULT (03),
NONE (01)
INVERSE FAULT (04), FAULT LOCKOUT (05),
AT SET SPEED (06), ABOVE PRESET #3 (07),
CURRENT LIMIT (08), AUTO SPEED (09),
REVERSE (10)
10
TB-13A FUNCTION
NONE (01), 0-10 VDC(02), 4-20mA (03),
NONE (01)
SELECT
PRESET SPEED #1 (04), START FWD (05),
RUN REVERSE (06), START REVERSE (07),
REMOTE KEYPAD (08), DB FAULT (09),
AUXILIARY STOP (10), ACCEL/DECEL #2 (11)
11
TB-13B FUNCTION
NONE (01), 0-10 VDC (02), 4-20mA (03),
NONE (01)
SELECT
PRESET SPEED #2 (04), DECREASE FREQ (05),
START FORWARD (06), JOG FORWARD (07),
JOG REVERSE (08), EXTERNAL FAULT (09),
INVERSE EXT FAULT (10), AUXILIARY STOP (11),
ACCEL/DECEL #2 (12), REMOTE KEYPAD (13)