LEESON SM Series Sub-Micro Inverters User Manual

Page 30

Advertising
background image

26

14.0

PARAMETER MENU

FACTORY

NO.

PARAMETER NAME

RANGE OF ADJUSTMENT

DEFAULT

01

LINE VOLTAGE

HIGH (01), LOW (02)

HIGH (01)

02

CARRIER FREQUENCY

4kHz (01), 6kHz (02), 8kHz (08), 10 kHz (04)

6 kHz (02)

03

START METHOD

NORMAL (01), START ON POWER UP (02),

NORMAL (01)

START WITH DC BRAKE (03),

AUTO RESTART WITH DC BRAKE (04),

FLYING RESTART 1 (05,) FLYING RESTART 2 (06),

FLYING RESTART 3 (07)

04

STOP METHOD

COAST (01), COAST WITH DC BRAKE (02),

COAST (01)

RAMP (03), RAMP WITH DC BRAKE (04)

05

STANDARD SPEED

KEYPAD (01), PRESET #1 (02),

KEYPAD (01)

SOURCE

0-10 VDC (03), 4-20 mA (04)

06

RELAY OUTPUT

NONE (01), RUN (02) ,FAULT (03),

NONE (01)

INVERSE FAULT (04), FAULT LOCKOUT (05),

AT SET SPEED (06), ABOVE PRESET #3 (07),

CURRENT LIMIT (08), AUTO SPEED (09),

REVERSE (10)

10

TB-13A FUNCTION

NONE (01), 0-10 VDC(02), 4-20mA (03),

NONE (01)

SELECT

PRESET SPEED #1 (04), START FWD (05),

RUN REVERSE (06), START REVERSE (07),

REMOTE KEYPAD (08), DB FAULT (09),

AUXILIARY STOP (10), ACCEL/DECEL #2 (11)

11

TB-13B FUNCTION

NONE (01), 0-10 VDC (02), 4-20mA (03),

NONE (01)

SELECT

PRESET SPEED #2 (04), DECREASE FREQ (05),

START FORWARD (06), JOG FORWARD (07),

JOG REVERSE (08), EXTERNAL FAULT (09),

INVERSE EXT FAULT (10), AUXILIARY STOP (11),

ACCEL/DECEL #2 (12), REMOTE KEYPAD (13)

Advertising