Troubleshooting, Localización de averías dépannage – Lincoln Electric IMT825 WELD-PAK 175 HD User Manual

Page 39

Advertising
background image

39

No wire feed, weld output or gas flow when gun trig-

ger is pulled. Fan does NOT operate.

1.

Make sure correct voltage is applied to the

machine.

2.

Make certain that power switch is in the ON

position.

3.

Make sure circuit breaker inside wire drive com-

partment is reset.

No wire feed, weld output or gas flow when gun trig-

ger is pulled Fan operates normally.

1.

The thermostat may be tripped due to overheat-

ing. Let machine cool. Weld at lower duty cycle.

2.

Check for obstructions in air flow. Check Gun

Trigger connections. See Installation section.

3.

Gun trigger may be faulty.

No wire feed when gun trigger is pulled. Fan runs,

gas flows and machine has correct open circuit volt-

age (32 VDC maximum) – weld output.

1.

If the wire drive motor is running make sure that

the correct drive rolls are installed in the

machine.

2.

Check for clogged cable liner or contact tip.

3.

Check for proper size cable liner and contact

tip.

TROUBLESHOOTING

Cuando se presiona el gatillo de la antorcha, no hay

alimentación de alambre, salida de soldadura ni flujo

de gas. El ventilador NO funciona.

1.

Asegúrese de aplicar el voltaje correcto a la

máquina.

2.

Asegúrese de que el interruptor de energía esté

en la posición de ENCENDIDO.

3.

Asegúrese de restablec‘r el interruptor

automático que se encuentra dentro del com-

partimiento del mecanismo de alimentación de

alambre.

Cuando se presiona el gatillo de la antorcha, no hay

alimentación de alambre, salida de soldadura ni flujo

de gas. El ventilador funciona normalmente.

1.

El termostato puede estar abierto debido a un

sobrecalentamiento. Deje enfriar la máquina.

Suelde en el ciclo de trabajo más bajo.

2.

Revise que no haya obstrucciones en el flujo

de aire. Revise las conexiones del Gatillo de la

Antorcha. Vea la sección de Instalación.

3.

El gatillo de la antorcha puede estar defectu-

oso.

Cuando se presiona el gatillo de la antorcha, no hay

alimentación de alambre. El ventilador funciona, el

gas fluye y la máquina tiene el voltaje de circuito abier-

to (máximo de 32vcd) – en la salida de soldadura.

1.

Si el motor impulsor de alambre está funcionan-

do, asegúrese de que se hayan instalado los

rodillos impulsores correctos en la máquina.

2.

Verifique que la guía de alambre o la punta del

contacto no tengan obstrucciones.

3.

Verifique que la guía de alambre y la punta de

contacto sean del tamaño adecuado.

LOCALIZACIÓN DE AVERíAS

DÉPANNAGE

If for any reason you do not understand the test pro-

cedures or are unable to perform the tests/repairs

safely, contact your LOCAL AUTHORIZED LIN-

COLN ELECTRIC FIELD SERVICE FACILITY for

assistance before you proceed.

CAUTION

Si por cualquier razón no entiende los procedimientos de

prueba, o no puede realizar las pruebas/reparaciones de

manera segura, antes de continuar contacte AL TALLER

DE SERVICIO DE CAMPO AUTORIZADO DE LINCOLN

para obtener asesoría sobre la localización de averías.

ADVERTENCIA

Pas de dévidage, de sortie de soudage ou d'écoule-

ment de gaz quand on appuie sur la gâchette. Le

ventilateur NE FONCTIONNE PAS.

1.

S'assurer que la bonne tension est appliquée à

la machine.

2.

S'assurer que l'interrupteur d'alimentation est

sur marche (“I”).

3.

S'assurer que le disjoncteur à l'intérieur du

compartiment dévidoir est réenclenché.

Pas de dévidage, de sortie de soudage ou d'écoule-

ment de gaz quand on appuie sur la gâchette du pis-

tolet. Le ventilateur FONCTIONNE NORMALEMENT.

1.

Le thermostat peut s'être déclenché en raison

d'une surchauffe. Laisser la machine refroidir.

Souder à un facteur de marche inférieur

2.

Vérifier si la circulation d'air est bouchée.

Vérifier les connexions de la gâchette du pisto-

let. Voir la section Installation.

3.

La gâchette du pistolet peut être défectueuse.

Pas de dévidage quand on appuie sur la gâchette. Le

ventilateur tourne, le gaz s'écoule et la machine a la

bonne tension à vide (32 V c.c. maximum) - sortie de

soudage.

1.

Si le moteur d'entraînement du fil fonctionne,

s'assurer que les galets d'entraînement appro-

priés sont installés dans la machine.

2.

Vérifier si le conduit intérieur ou le tube contact

est bouché.

3.

Vérifier que le conduit intérieur et le tube con-

tact sont de la bonne dimension.

Si pour une raison ou une autre vous ne comprenez pas les

modes opératoires d'essai ou êtes incapable d'effectuer les

essais ou les réparations en toute sécurité, communiquez

avec votre SERVICE APRÈS-VENTE LOCAL AGRÉÉ PAR

LINCOLN qui vous prêtera assistance avant de poursuivre.

AVERTISSEMENT