Yokogawa EJA220A User Manual

Page 59

Advertising
background image

IM 01C21C01-01E

10-2

10. GENERAL SPECIFICATIONS

HART
Communication Distance;

Up to 1.5 km (1 mile) when using multiple twisted
pair cables. Communication distance varies
depending on type of cable used.
Use the following formula to determine cable
length for specific applications:

L=

-

65 x 10

6

(R x C)

(C

f

+ 10,000)

C

Where:
L = length in meters or feet
R = resistance in

Ω (including barrier resistance)

C = cable capacitance in pF/m or pF/ft
C

f

= maximum shunt capacitance of receiving

devices in pF/m or pF/ft

Physical Specifications

Wetted Parts Materials:
High side:

See ‘Model and Suffix Codes’

Low side:

Diaphragm;

Hastelloy C-276

Cover flange;

SCS14A

Process connector;

SCS14A

Capsule gasket;

Teflon-coated SUS316L

Drain/Vent plug;

SUS316

Process connector gasket;

PTFE Teflon

Non-wetted Parts Materials:

Bolting;

SCM435, SUS630, or SUH660

Housing;

Low copper cast-aluminum alloy with polyurethane
paint (Munsell 0.6GY3.1/2.0)

Degrees of Protection

IP67, NEMA4X, JIS C0920 immersion proof

Cover O-rings;

Buna-N

Data plate and tag;

SUS304 or SUS316 (optional)

Fill Fluid;

Silicone or Fluorinated oil (optional)

Weight:

EJA210A with 150# flange 11 kg(25 lb)
EJA220A with 150# flange 16 kg(35 lb)

Connections:

Refer to the ‘Model and Suffix Codes’ to specify
the process and electrical connection type.
The high pressure side is a flange connected, and
low side is threaded.

Atmospheric
pressure

-40
(-40)

0
(32)

40
(104)

80
(176)

120
(248)

1{0.14}

2.7{0.38}

10{1.4}

{psi abs}

100{14.5}

Process temperature

°C (°F)

Working
pressure
kPa abs

Applicable range

F1001.EPS

Figure 1. Working Pressure and Process Temperature

< Settings When Shipped > “

Tag Number

Output Mode

Display Mode

Operation Mode

Damping Time

Constant

As specified in order

*1

‘Linear’

‘2 sec.’

‘Normal’ unless otherwise specified in order

‘Linear’

Calibration Range

Units

As specified in order

As specified in order

Selected from mmH

2

O, mmAq, mmWG,

mmHg, Pa, hPa, kPa, MPa, mbar, bar,
gf/cm

2

, kgf/cm

2

, inH

2

O, inHg, ftH

2

O, or psi.

(Only one unit can be specified)

Calibration Range

Higher Range Value

Calibration Range

Lower Range Value

M1003.EPS

*1:

Up to 16 alphanumeric characters (including - and
· ) will be entered in the amplifier memory.

Advertising
This manual is related to the following products: