Customer maintenance parts list, Dpharp eja series transmitter section – Yokogawa EJA220A User Manual

Page 67

Advertising
background image

Customer
Maintenance
Parts List

All Rights Reserved, Copyright © 1997, Yokogawa Electric Corporation.

Subject to change without notice. Printed in Japan.

Yokogawa Electric Corporation

CMPL 01C21A01-02E

11th Edition: Oct. 2008(KP)

DPharp EJA Series
Transmitter Section

Cover
Cast-aluminum alloy
SCS14A stainless steel
O-ring
Case Assembly (Note 1)

Cast-aluminum alloy for G1/2
Cast-aluminum alloy for G1/2 (two electrical connections)
Cast-aluminum alloy for 1/2 NPT (two electrical connections)
Cast-aluminum alloy for M20 (two electrical connections)
Cast-aluminum alloy for Pg13.5 (two electrical connections)

SCS14A stainless steel for 1/2 NPT (two electrical connections)

Name Plate
Screw

For cast-aluminum alloy case assembly
For SCS14A stainless steel case assembly

Tag Plate
CPU Assembly

For BRAIN protocol version
For HART protocol version
For BRAIN protocol version(Optional code /F1)

For HART protocol version with write protection switch (Optional code /F1)
For F

OUNDATION

Fieldbus protocol version

For F

OUNDATION

Fieldbus protocol version with PID/LM function (Optional code /LC1)

Cap Screw
Screw

Plug

For Pg13.5
For M20
For G1/2
For 1/2 NPT

Cover Assembly

Cast-aluminum alloy
SCS14A stainless steel

LCD Board Assembly

Without range-setting switch

With range-setting switch

Mounting Screw
Label


1

2
3

4
5

6
7-1

7-2

8
9

10


11

12

13
14

Bellow

F9341RA
F9341RJ
F9341JP

Below

F9341AA
F9341AC
F9341AE
F9341AH
F9341AJ

F9341AR

Bellow

F9900RG
F9900RR

F9341KL

Below

F9342AB
F9342AL
F9342AF

F9342AM
F9342BF
F9342BG
F9900RP
Y9612YU

Below

F9340NW
F9340NX
G9330DP
G9612EB

Bellow

F9341FM
F9341FJ

Below

F9342BL

F9342BM
F9342MK
F9300PB

2

2
1

1
4

1
1

1

2
2

1

1

1

2
2

Item

Part No.

Description

Qty

For integral indicator

(Note 1) Applicable for BRAIN and HART protocol versions (Output signal code D and E). For F

OUNDATION

Fieldbus protocol

version (Output signal code F), consult Yokogawa local office.

13

12

14

2

11

A

A

4

10

3

8

7-1

9

6

5

2

1

5

2

1

7-2