2 model and suffix codes, 2 model and suffix codes -3, Model eja210a – Yokogawa EJA220A User Manual

Page 60

Advertising
background image

IM 01C21C01-01E

10-3

10. GENERAL SPECIFICATIONS

10.2

Model and Suffix Codes

Model EJA210A

Model

Suffix Codes

Description

EJA210A

Output Signal

Measurement span
(capsule)

High pressure side
(Process flange side)
wetted parts material

(Note 2)

Process flange rating

Process flange
size/material

Low pressure side process
connection

Bolts and nuts material

Installation

Electrical connection

Integral indicator

Optional codes

Flange-mounted differential pressure transmitter
(Flush diaphragm type)

4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART protocol)
Digital communication (F

OUNDATION

Fieldbus protocol)

Digital communication (PROFIBUS PA protocol)

1 to 100 kPa {100 to 10000 mmH

2

O}

5 to 500 kPa {0.05 to 5 kgf/cm

2

}

[Diaphragm] [Others]
SUS316L

SUS316

Hastelloy C-276

Hastelloy C-276

Tantalum

Tantalum

Hastelloy C-276

SUS316

JIS10K
JIS20K
ANSI Class 150
ANSI Class 300
JPI Class150
JPI Class 300
DIN PN10/16
DIN PN25/40

3-inch (80 mm) /S25C
3-inch (80 mm) /SUS304
3-inch (80 mm) /SUS316
2-inch (50 mm) /SU25C
2-inch (50 mm) /SUS304
2-inch (50 mm) /SUS316

without process connector (Rc1/4 female on the cover flange)
with Rc1/4 female process connector
with Rc1/2 female process connector
with 1/4NPT female process connector
with 1/2NPT female process connector
without process connector (1/4 NPT female on the cover flange)

SCM435
SUS630
SUH660

Horizontal impulse piping type, left side high pressure

G1/2 female, one electrical connection
1/2 NPT female, two electrical connections without blind plug
Pg 13.5 female, two electrical connections without blind plug
M20 female, two electrical connections without blind plug
G1/2 female, two electrical connections and a blind plug
1/2 NPT female, two electrical connections and a blind plug
Pg 13.5 female, two electrical connections and a blind plug
M20 female, two electrical connections and a blind plug
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug

Digital indicator
Digital indicator with the range setting switch
(None)

Always N

. . . . . . . . . . . . . . . . . . . . .

-D . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . .

(Note 1)

-F . . . . . . . . . . . . .

(Note 5)

-G . . . . . . . . . . . . .

(Note 6)

M . . . . . . . . . . . . . . . . .
H . . . . . . . . . . . . . . . . . .

S . . . . . . . . . . .

(Note 3)

H . . . . . . . . . . .

(Note 3)

T . . . . . . . . . . .

(Note 3)

W . . . . . . . . . .

(Note 4)

J1 . . . . . . . . . . . . . .
J2 . . . . . . . . . . . . . .
A1 . . . . . . . . . . . . . .
A2 . . . . . . . . . . . . . .
P1 . . . . . . . . . . . . . .
P2 . . . . . . . . . . . . . .
D2 . . . . . . . . . . . . . .
D4 . . . . . . . . . . . . . .

D . . . . . . . . . . . . . .
E . . . . . . . . . . . . . .
F . . . . . . . . . . . . . .
A . . . . . . . . . . . . . .
B . . . . . . . . . . . . . .
C . . . . . . . . . . . . . .

0 . . . . . . . . . . . . .
1 . . . . . . . . . . . . .
2 . . . . . . . . . . . . .
3 . . . . . . . . . . . . .
4 . . . . . . . . . . . . .
5 . . . . . . . . . . . . .

A . . . . . . . . . . .
B . . . . . . . . . . .
C . . . . . . . . . . .

-9 . . . . . . . . . .

0 . . . . . . . . .
2 . . . . . . . . .
3 . . . . . . . . .
4 . . . . . . . . .
5 . . . . . . . . .
7 . . . . . . . . .
8 . . . . . . . . .
9 . . . . . . . . .
A . . . . . . . .
C . . . . . . . .
D . . . . . . . .

D . . . . . . . .
E . . . . . . . .
N . . . . . . . .

N . . . . . .

/

ᮀ Optional specification

T1002.EPS

Example: EJA210A-DMSA1D5A-92NN/

Note 1: Refer to IM 01C22T01-01E for HART Protocol version.
Note 2: Low pressure side wetted parts material: Cover flange; SCS14A, Process connector; SCS14A,

Capsule; SUS316L (Diaphragm; Hastelloy C-276), Vent plug; SUS316

Note 3: Applicable only for 3-inch (80 mm) flange size (Process flange size/material codes D and E)
Note 4: Applicable only for 2-inch (50 mm) flange size (Process flange size/material codes A and B)
Note 5: Refer to IM 01C22T02-01E for Fieldbus communication.
Note 6: Refer to IM 01C22T03-00E for PROFIBUS PA communication.

Advertising
This manual is related to the following products: