• Turnng ON/OFF the Perodc Prntout

Periodic printout can be turn ON/OFF. By default, periodic printout is enabled with the

interval synchronized to the chart speed. Also, the measured values that are printed
are the instantaneous values.

Manual Prntout

Measured values and alarm status can be printed manually using the keys. When
manual printout is executed, trend recording stops and restarts when manual printout is
complete.

Message Prntout

Printout is not performed when the chart speed is as follows:
Pen model: 1600 mm/h or greater. Dot model: 51 mm/h or greater (18-dot and 24-dot

models) and 101 mm/h or greater (6-dot and 12-dot models).

Preset messages can be printed on the chart paper using the keys. Five messages, each
within 16 characters, can be registered in advance.
• If message printout is executed while another message is being printed, the most

recent message is temporarily stored to the buffer memory in a printout-wait condition.
Messages are cleared from the buffer memory when they are printed.

• The number of messages that can be stored in the buffer is 5. If message printout is

executed when the buffer is full, the message is not printed. A buffer overflow mark is
printed when there are messages that cannot be printed because the buffer is full.

• The time printout format can be selected.

New Chart Speed Prntout

Printout is not performed when the chart speed is as follows:
Pen model: 1600 mm/h or greater. Dot model: 51 mm/h or greater (18-dot and 24-dot

models) and 101 mm/h or greater (6-dot and 12-dot models).

• When the chart speed is changed, the time tick (dot model), the date/time of change,

and the new chart speed are printed. An asterisk (*) shows there are messages that
cannot be printed.

• The time printout format can be selected.

Recordng Start Prntout

Printout is not performed when the chart speed is as follows:
Pen model: 1600 mm/h or greater. Dot model: 51 mm/h or greater (18-dot and 24-dot

models) and 101 mm/h or greater (6-dot and 12-dot models).

When recording is started, the time tick (dot model), the time, and the chart speed can be
printed. An asterisk (*) shows there are messages that cannot be printed.
• The recording start printout can be enabled or disabled. By default, the recording start

printout is disabled.

• The time printout format can be selected.

Prntout/Dsplay Format of the Date

The printout/display format of the date can be selected from the list below. The setting
applies to all dates printed and shown on the display. However, this does not apply to
the format of the date printout of the message printout that include the measured values
(/BT1 option).

Type

Prntout/Dsplay Format

Y/M/D

2005/08/31

M/D/Y

08/31/2005

D/M/Y

31/08/2005

D.M.Y

31.08.2005

M.D.Y

Aug.31.2005

<Related Topcs> Setting the printout/display format of the date: Section 7.19