IM 04P02B01-01E

1-34

1.10 Functon Setup Gude

This section explains the settings necessary to use various functions of the recorder.
Read the section corresponding to the function you wish to use.

Note

This section contains all the settings related to each item. If the desired setting is the same as
the default value, you do not have to set it.

Item

Descrpton

Reference

Secton

Date/Time setting

Use

Clock in Setting mode

5.5

DST

Sets the date/time for switching between DST and standard time using

Aux > DST in

Setting mode.

6.16

Setting initialization

Use

Intalze in Basic Setting mode to initialize the settings of Setting mode and Basic

Setting mode to their default values.

7.17

Measurng nput functons

Item

Descrpton

Reference

Secton

Range and span of the TC, RTD, or DC voltage

Use

Range in Setting mode.

5.1

1-5V

• Range, span, and scale

5.1

Use

Range in Setting mode.

• Unit

5.3

Use

Unt in setting mode to set the unit after scaling.

• Low-cut

7.15

Use

Personalze > Add functon > 1-5V low-cut in Basic Setting mode and select

Use or Not.

5.1

If Use is selected, turn On/Off

Low-cut using Range in Setting mode.

If Not is selected, the

Low-cut item does not appear in the Range setting.

Scaling

• Range, span, and scale

5.1

Use

Range in Setting mode.

• Unit

5.3

Use

Unt in setting mode to set the unit after scaling.

Square Root Computation • Range, span, and scale

5.1

Use

Range in Setting mode.

• Unit

5.3

Use

Unt in setting mode to set the unit after scaling.

• Low-cut

7.15

Use

Personalze > Add functon > SQRT low-cut in Basic Setting mode and select

Use or Not.

If Use is selected, set the

Low-cut pont using Range in Setting mode.

5.1

If Not is selected, the

Low-cut item does not appear in the Range setting.

Unused channels

Use

Range > Skp in Setting mode to disable the trend recording (dot model) and

periodic printout of the target channel.

5.1

Bias

Use

Personalze > Add functon > Bas in Basic Setting mode and select Use or Not. 7.15

If Use is selected, set the bias value that is added to the input using

Bas in Setting

mode. If Not is selected, the

Bas item does not appear.

6.12

Burnout detection function (TC input and 1-5V input)

7.3

Use

Burnout in Basic Setting mode to set the burnout detection function for each

channel.

RJC of TC input

Use

RJC in Basic Setting mode to select whether to use the internal RJC function or

an external RJC function.

7.4

Filter (pen model)

Use

Flter in Basic Setting mode and select Use or Not.

7.12

If Use is selected, set the filter time constant using

Aux > Flter in Setting mode.

6.2

If Not is selected, the

Aux > Flter item does not appear.