137
For P<31, two additional power limits (shown below)
can be selected via the
Additional Max Out. Pwr
option for Home BS applications:
(The default value for Δfmax is 14.5 MHz. Δfmax can
be user-defined)
6≤P≤20
Unit: MHz
Abs
[1]
RBW
12.5 ≤E< Δfmax P- 56dB
1MHz
P<6
Unit: MHz
Abs
[1]
RBW
12.5 ≤E< Δfmax -50dBm
1MHz
3GPP-FDD BS
Additional
Requirements
For operation in bands II, IV, V, X, XII, XIII, XIV and
XXV, additional requirements (listed below) apply in
addition to the minimum requirements listed above.
Bands:
II, IV, X
Unit: MHz
Additional
[3]
RBW
2.5 ≤A<3.5
-15dBm
30kHz
3.5≤B< Δfmax -13dBm
1MHz
Bands: V
Unit: MHz
Additional
[3]
RBW
2.5 ≤A<3.5
-15dBm
30kHz
3.5≤B< Δfmax -13dBm
100kHz
Bands:
XII, XIII, XIV
Unit: MHz
Additional
[3]
RBW
2.5 ≤A<3.5
-13dBm
30kHz
3.5≤B< Δfmax -13dBm
100kHz
3GPP-FDD UE
The channel span is set to 5MHz.
Note: A, B, C, D, E denote offsets 1 to 5, respectively.
Unit: MHz
Rel
Abs
[1]
RBW
2.5 ≤A<3.5 -35~-50dBc
-71.1dBm
30kHz
3.5 ≤B<7.5 -35~-39dBc
-55.8dBm
1MHz
7.5 ≤C<8.5 -39~-49dBc
-55.8dBm
1MHz
8.5 ≤D<12.5 -49~-49dBc
-55.8dBm
1MHz