Data logging power meter measurements, Ge 175 – GW Instek GSP-930 User Manual User Manual
Page 177

ADVANCED OPERATION
175
MIN HOLD
measurement
MIN HOLD
measurement
Note
The return to the Spectrum Mode, press
Mode
>
Spectrum[F1]
.
Data Logging Power Meter Measurements
Description
When in Power Meter mode, the spectrum
analyzer is able to log the power meter
measurements over a user-defined time period
at user-defined intervals.
Operation
1. Press
Save
to enter the save menu.
2. Press Type[F2] and select Power Meter[F7].
3. Press Data Source[F3] and select Power State[F1].
4. Press PMET Record Option[F4] and set the
recording options:
Record Stop[F1]:
Sets the recording time for
automatic data logging:
00 :00 :00 (continuous) or
00 :00 :01 ~ 23 : 59: 59
Record Step[F2]:
1sec ~ 999sec
5. Press Save To[F1] and select a destination
source:
Register 1~6:
Internal memory registers,
these internal registers are not
part of local memory
Local:
Internal memory