GW Instek AFG-2225 User Manual User Manual
Page 112

AFG-2225 Series User Manual
112
Range
Center frequency
1μHz~25MHz (sine wave)
1μHz~1MHz (Ramp wave)
1μHz~15MHz (square wave)
Span frequency
DC~25MHz
(sine wave)
DC ~1MHz (Ramp wave)
1μHz~15MHz (square wave)
Default center
550Hz
Default span
900Hz
Note
To sweep from low to high frequencies, set a
positive span.
To sweep from high to low frequencies, set a
negative span.
When marker is off, the SYNC signal is a square
wave with a duty cycle of 50%. At the start of the
sweep, the SYNC signal is at a TTL low level that
rises to a TTL high level at the frequency midpoint.
The frequency of the SYNC signal is equal to the
sweep time.
When marker is on, at the start of the sweep, the
SYNC signal is at a TTL high level that drops to a
TTL low level at the marker. The SYNC signal is
output from the mark output terminal.