Source[1|2]:sweep:spacing, Source[1|2]:sweep:time – GW Instek AFG-2225 User Manual User Manual
Page 245

REMOTE INTERFACE
245
SOURce[1|2]:SWEep:SPACing
Source Specific
Command
Description
Sets linear or logarithmic sweep spacing. The
default spacing is linear.
Syntax
SOURce[1|2]:SWEep:SPACing {LINear|LOGarithmic}
Example
SOUR1:SWE:SPAC LIN
Sets the spacing to linear.
Query Syntax
SOURce[1|2]:SWEep:SPACing?
Return Parameter LIN
Linear spacing
LOG
Logarithmic spacing
Example
SOUR1:SWE:SPAC?
LIN
The spacing is currently set as linear.
SOURce[1|2]:SWEep:TIME
Source Specific
Command
Description
Sets or queries the sweep time. The default sweep
time is 1 second.
Note
The function generator automatically determines
the number of frequency points that are used for
the sweep based on the sweep time.
Syntax
SOURce[1|2]:SWEep:TIME
{<seconds>|MINimum|MAXimum}
Parameter
<seconds>
1 ms ~ 500 s
Example
SOUR1:SWE:TIME +1.0000E+00
Sets the sweep time to 1 second.
Query Syntax
SOURce[1|2]:SWEep:TIME? {<seconds>|
MINimum|MAXimum}
Return Parameter <NR3>
Returns sweep time in
seconds.