<offset>
0~4.99V (50Ω)
Example
SOUR1:APPL:TRI 2khz, 3.0, 1.0
Sets the frequency to 1 MHz with an amplitude of
3 volts and with an offset of 1 volt.
SOURce[1]:APPLy:DC
Source Specific
Command
Description
Outputs a triangle wave from the selected channel
when the command has executed. Frequency,
amplitude and offset can also be set.
Note
Frequency and amplitude cannot be used with the
DC function; however a value (or DEFault) must
be specified. The values are remembered for the
next function used.
Syntax
SOUR[1]:APPLy:DC [<frequency|DEFault>
[,<amplitude>|DEFault> [,<offset>] ]]
Parameter
<frequency>
Not applicable
<
amplitude
> Not
applicable
<offset>
±5V (50Ω), ±10V (open)
Example
SOUR1:APPL:DC DEF, DEF, 1.0
Sets the DC offset to 1 volt.
SOURce[1]:APPLy:USER
Source Specific
Command
Description
Outputs an arbitrary waveform from the selected
channel. The output is that specified from the
FUNC:USER command.
Note
Frequency and amplitude cannot be used with the
DC function; however a value (or DEFault) must
be specified. The values are remembered for the
next function used.
Syntax
SOURce[1]:APPLy:USER [<frequency> [,<amplitude>
[,<offset>] ]]