Source[1]:arb:built:ramp, Source[1]:arb:built:sinc – GW Instek AFG-3000 Series User Manual
Page 269

REMOTE
INTERFACE
269
SOURce[1]:ARB:BUILt:RAMP
Source Specific
Command
Description
Creates a ramp wave with a specified start
address, length and scale.
Syntax
SOURce[1]:ARB:BUILt:RAMP[<STARt>[,<LENGth>[,<S
CALe>]]]
Parameter
<STARt>
Start address*: 0~1048,576
<LENGth>
Length*: 0 ~ 1048,576
<SCALe> Scale:
±32767
* Start + Length ≤ 1,048,576
Example
SOUR1:ARB:BUIL:RAMP 1000, 1000, 100
Creates a ramp wave 1000 points in length with a
scale of 100 and a start address of 1000.
SOURce[1]:ARB:BUILt:SINC
Source Specific
Command
Description
Creates a sinc wave with a specified start address,
length and scale.
Syntax
SOURce[1]:ARB:BUILt:SINC
[<STARt>[,<LENGth>[,<SCALe>]]]
Parameter
<STARt>
Start address*: 0~1048,576
<LENGth>
Length*: 0 ~ 1048,576
<SCALe> Scale:
±32767
* Start + Length ≤ 1,048,576
Example
SOUR1:ARB:BUIL:SINC 1000, 1000, 100
Creates a sinc wave 1000 points in length with a
scale of 100 and a start address of 1000.