GW Instek AFG-3000 Series User Manual
Page 292

AFG-3000 Series User Manual
292
Bit Summary
Register
Bit
Bit Weight
Operation complete bit
0
1
Query Error
2
4
Device Error
3
8
Execution Error
4
16
Command Error
5
32
Power On
7
128
Error Bits
Operation
complete
The operation complete bit is set
when all selected pending
operations are complete. This bit is
set in response to the *OPC
command.
Query Error The Query Error bit is set when
there is an error reading the Output
Queue. This can be caused by trying
to read the Output Queue when
there is no data present.
Device Error The Device Dependent Error
indicates a failure of the self-test,
calibration, memory or other device
dependent error.
Execution
Error
The Execution bit indicates an
execution error has occurred.
Command
Error
The Command Error bit is set when
a syntax error has occurred.
Power On
Power has been reset.