Source[1]:arb:built:pulse – GW Instek AFG-3000 Series User Manual
Page 268

AFG-3000 Series User Manual
268
Parameter
<STARt>
Start address*: 0~1048,576
<LENGth>
Length*: 0 ~ 1048,576
<SCALe> Scale:
±32767
* Start + Length ≤ 1,048,576
Example
SOUR1:ARB:BUIL:SQU 1000, 1000, 100
Creates a square wave 1000 points in length with a
scale of 100 and a start address of 1000.
SOURce[1]:ARB:BUILt:PULSe
Source Specific
Command
Description
Creates a pulse wave with a specified frequency
and duty.
Syntax
SOURce[1]:ARB:BUILt:PULSe
[<FREQuency>[,<DUTY>]]
Parameter
<FREQuency>
1pHz~500kHz*
<DUTY>
0.0001%~99.9999%
*Frequency
Resolution
Duty
Resolution
1pHz~5Hz
1pHz
0.0001%
>5Hz~50Hz
1uHz
0.0001%
>50Hz~500Hz
10uHz
0.001%
>500Hz~5kHz
100uHz
0.01%
>5kHz~50kHz
1mHz
0.1%
>50kHz~500kHz
10mHz
1%
Example
SOUR1:ARB:BUIL:PULSe +1.00000002E+03,
+1.002E+01
Creates a 1000.0002Hz pulse wave with a 10.02%
duty cycle.