Source[1]:frequency:start, Source[1]:frequency:stop – GW Instek AFG-3000 Series User Manual
Page 243

REMOTE
INTERFACE
243
SOURce[1]:FREQuency:STARt
Source Specific
Command
Description
Sets the start frequency of the sweep. 100Hz is the
default start frequency.
Note
To sweep up or down, set the stop frequency
higher or lower than the start frequency.
Syntax
SOURce[1]:FREQuency:STARt
{<frequency>|MINimum|MAXimum}
Parameter
<frequency>
100μHz~ 80MHz(3081)/
50MHz(3051)
100μHz~ 1MHz (Ramp)
Example
SOUR1:FREQ:STAR +2.0000E+03
Sets the start frequency to 2kHz.
Query Syntax
SOURce[1]:FREQuency:STARt? [MINimum|
MAXimum]
Return Parameter <NR3>
Returns the start frequency
in Hz.
Example
SOUR1:FREQ:STAR? MAX
+8.0000E+07
Returns the maximum start frequency allowed.
SOURce[1]:FREQuency:STOP
Source Specific
Command
Description
Sets the stop frequency of the sweep. 1 kHz is the
default start frequency.
Note
To sweep up or down, set the stop frequency
higher or lower than the start frequency.
Syntax
SOURce[1]:FREQuency:STOP
{<frequency>|MINimum|MAXimum}
Parameter
<frequency>
100μHz~ 80MHz(3081)/
50MHz(3051)
100μHz~ 1MHz (Ramp)