Caution, Pvcheck – HT instruments PVCHECK User Manual
Page 23

PVCHECK
EN - 21
5.6.1. How to define a new PV module
1. Position the cursor onto DB by using the arrow keys
(
,) and confirm with ENTER. The display shows the
screen which contains:
The type of PV module
The values of the parameters associated to the module
(see Table 1)
2. Use the arrow keys (
, ) to select the “DEFAULT”
module type and confirm with ENTER.
15/05/12 15:34:26
M o d e l : D E F A U L T
P m a x
=
1 8 5
W
V o c =
4 4 . 5
V
V m p p
=
3 7 . 5
V
I s c
=
5 . 4 0
A
I m p p =
4 . 9 5
A
T o l l - =
0
%
Selection
D B
3. Press the ENTER key, select the “New” command (which
allows defining a new module) and confirm again with
ENTER. Use the arrow keys (
,) to scroll the list of
parameters.
15/05/12 15:34:26
M o d e l : D E F A U L T
P m a x
=
1 8 5
W
V o c =
4 4 . 5
V
V m p p
=
3 7 . 5
V
I s c
=
5 . 4 0
A
I m p p =
4 . 9 5
A
T o l l - =
0
%
N e w
Selection
D B
4. By using the internal virtual keyboard it is possible to
define the name of the module (e.g. SUNPOWER 210) by
means of the arrow keys (
,, , ). Press ENTER to
digit any character of the desired name.
5. Press the SAVE key to save the name of the new module
thus defined or the ESC/MENU key to exit without saving.
15/05/12 15:34:26
M o d e l :
P m a x
=
1 8 5
W
V o c =
4 4 . 5
V
K E Y B O A R D
S U N P O W E R 2 1 0
A B C D E F G H I J K L M N O P
Q R S T U V W X Y Z - +
0
1 2 3
4 5 6 7 8 9 S P A C E
D E L
SAVE / ESC
6. Insert the value of each parameter (see Table 1)
according to the possible datasheet of the Manufacturer.).
Position the cursor onto the parameter to be defined by
using the arrow keys (
,) and set the value using the
arrow keys (
, ). Keep the arrow keys ( , ) pressed
to carry out a quick setting of the values.
7. Press the SAVE key to save the settings or the
ESC/MENU key to exit without saving.
15/05/12 15:34:26
M o d e l : S U N P W R 2 1 0
P m a x
=
0
W
V o c =
0 . 0
V
V m p p
=
0 . 0
V
I s c
=
0 . 0 0
A
I m p p =
0 . 0 0
A
T o l l -
=
0
%
D B
CAUTION
If the value of any parameter is unknown, press and hold the HELP key
for a few seconds to set the default values.
Upon pressing the SAVE key, the instrument checks the conditions
indicated in Table 1
and, if one or more of these conditions are not fulfilled, one of the error
messages listed in § 6.6 is shown on the display. The instrument does not
save the configuration set before any error is solved.