5. Connect the DC current clamp to the positive output conductor of the string,

respecting the direction of the arrow found on the clamp itself as indicated in Fig. 5.
Position the clamp so that the jaw is not near the negative conductor.


6. The display shows the first screen which contains the

values of the output electrical parameters of the
module/string.

15/05/12 15:34:26

I r r

- - -

W / m 2

P n o m 3 . 5 0 0

k W

T c

- - -

° C

T e

- - -

° C

P d c

3 . 1 2 5

k W

V d c

3 8 9

V

I d c

8 . 0 1

A

n d c

- - -

G o t o S t a r t

Selection

E F F

7. Press GO/STOP key on PVCHECK to start the test. The

message “Waiting start recording…” appears on the
display of the instrument until “00” is reached.

15/05/12 15:34:26

I r r

- - -

W / m 2

P n o m 3 . 5 0 0

k W

T c

4 5

° C

T e

3 0

° C

P d c

3 . 1 2 5

k W

V d c

3 8 9

V

I d c

8 . 0 1

A

n d c

- - -

W a i t i n g s t a r t r e c o r d i n g …

Selection

E F F

8. Upon reaching “00” after pressing the GO/STOP key, the

test is started. Unser these conditions, the message
Recording running…” appears on the instrument’s
display.

15/05/12 15:35:00

I r r

- - -

W / m 2

P n o m 3 . 5 0 0

k W

T c

4 5

° C

T e

3 0

° C

P d c

3 . 1 2 5

k W

V d c

3 8 9

V

I d c

8 . 0 1

A

n d c

- - -

R e c o r d i n g r u n n i n g …

Selection

E F F

9. At any time it will be possible to analyze the current

recording status by pressing the MENU key. The following
information will be shown:
 Starting date and time of recording
 The value set for the integration period
 The number of periods elapsed from the beginning of the

recording

 The remaining memory capacity for recording

Press the ESC key to exit the screen

15/05/12 15:35:00

S t a r t : 1 4 / 0 2 / 0 0 1 7 : 1 8 : 0 0
P e r i o d : 5 s

I P N u m b e r 6 1

R e c . T i m e

0 d 1 h

R e c o r d i n g r u n n i n g …


10. To stop testing, press the GO/STOP key on the instrument and confirm with ENTER that

you want to stop recording.

11. Press SAVE to save the results obtained (see § 7.1) or ESC to exit the screen and go back

to the initial screen.