EN - 45

6.4.4.1. Anomalous

situations

1. In any operating mode, in case the instrument detects a

voltage higher than 1000V at terminals P-N, P-E and N-
E, it does not carry out the test, gives out a long sound
and displays the message “Vin > 1000”.

15/05/12 15:34:26

I n s . T e s t

:

1 0 0 0

V

R i m i n

:

1 . 0

M

M o d e :

S t r i n g

V t e s t

=

- - -

V

R p

=

- - -

M

Vin > 1000

Selection

M


2. In STRING mode, in case the instrument detects an Isc

current higher than 10A, it does not carry out the test,
gives out a long sound and displays the message “Isc
current too high”.

15/05/12 15:34:26

I n s . T e s t

:

1 0 0 0

V

R i m i n

:

1 . 0

M

M o d e :

S t r i n g a

V t e s t

=

- - -

V

R p

=

- - -

M

Isc current too high

Selection

M


3. In STRING mode, in case the instrument detects a

current < 0.2A between terminals P and N, it does not
carry out the test, gives out a long sound and displays
the message “Current < Lim”.

15/05/12 15:34:26

I n s . T e s t

:

1 0 0 0

V

R i m i n

:

1 . 0

M

M o d e :

S t r i n g

V t e s t

=

- - -

V

R p

=

- - -

M

Current < Lim

Selection

M


4. In STRING mode, in case the instrument detects a

voltage < 15V between terminals P and N, it does not
carry out the test and displays the message “Low
voltage”.

15/05/12 15:34:26

I n s . T e s t

:

1 0 0 0

V

R i m i n

:

1 . 0

M

M o d e :

S t r i n g

V t e s t

=

- - -

V

R p

=

- - -

M

Low voltage

Selection

M

Advertising