Overview of setup functions, Overview of setup functions 14 – Badger Meter Registers User Manual

Page 14

Advertising
background image

Industrial Registers, Models ER-420-AC, ER-420-DC & ER-420-LP

Overview of Setup Functions

Setup Functions and Variables
1

Total
11

UNIT

L, m

3

, kg, lb, GAL, USGAL, bbl, no unit

12

DECIMALS

0, 1, 2, 3 (Ref: displayed value)

13

K-FACTOR

0 000010…9,999,999 (see chart)

14

DECIMALS K-FACTOR

0…6

15

Multiplication factor

x1, x10, x100, x1000, x10000

2

Flow Rate
21

UNIT

mL, L, m

3

, mg, g, kg, ton, GAL, bbl, lb, cf, REV, no unit, scf, Nm

3

, NL, P, MGAL

22

TIME UNIT

sec, min, hour, day

23

DECIMALS

0, 1, 2, 3 (Ref: displayed value)

24

K-FACTOR

0 000010…9,999,999

25

DECIMALS K-FACTOR

0…6

26

CALCULATION

per 1…255 pulses

27

CUT-OFF

0 1…999 9 secs

3

Display
31

FUNCTION

total, flow rate

4

Power Management (Does Not Apply to This Unit)

5

Flowmeter
51

SIGNAL

npn, npn_lp, reed, reed_lp, pnp, pnp_lp, act_8 1, act_12, act_24

6

Analog
61

OUTPUT

disable, enable

62

4 mA

0000 000…9,999,999

63

20 mA

0000 000…9,999,999

64

CUT-OFF

0 0…9 9%

65

TUNE MIN, 4 mA

0…9,999

66

TUNE MAX, 20 mA

0…9,999

67

FILTER

00…99

7

Pulse for Versions Earlier than Rev. 03
71

PULSE WIDTH

0…250

72

PULSE PER

X,XXX,XXX quantity

Pulse for Versions Rev. 03 and Later
71

PULSE WIDTH

0 000…9 999 sec (0=Off)

72

DECIMALS

0, 1, 2, 3

73

AMOUNT

X,XXX,XXX quantity

8

Communication (Does Not Apply to This Unit)

9

Others
91

MODEL

F100-P

92

TYPE

ER-420LP / ER-420DC / ER-420AC

93

SOFTWARE VERSION

__ __ __

94

SERIAL NO

xxxxxxx

95

PASS CODE

0000…9999

96

TAGNUMBER

0000000…9999999

Page 14

May 2014

Advertising