^TS Select

template

[ASCII] ^ T S n1 n2 n3

[Decimal]

94 84 83 nd1 nd2 nd3

[Hexadecimal]

5E 54 53 nh1 nh2 nh3

[Parameters]

n1: 0 (Fixed)

0≤n2≤9

0≤n3≤9

[Description]

Specifies the number of the template selected from the machine.

(n2*10)+n3:

Template number (1 to 99)

The default selection number is 1.

This command is a dynamic command.

[Remarks]

The template numbers that can be set are between 1 and 99. This command becomes

invalid if any other value has been specified or if the number that has been specified is for

a template not transferred to the machine.

All data already fed in, selected objects and the search text are initialized.

[Example]

To select template number 99:

Since n2=9 and n3=9, the command will be as follows.

^ T S 0 9 9 (5Eh 54h 53h 30h 39h 39h)