Esc ixa2 specify non-printed text strings, Esc ixa2, Specify non-printed text strings – Brother PT-9700PC User Manual

Page 66

Advertising
background image

40

ESC iXa2

Specify non-printed text strings

[ASCII] ESC i X a 2 n1 n2 n3 data

[Decimal]

27 105 88 97 50 nd1 nd2 nd3 datad

[Hexadecimal]

1B 69 58 61 32 nh1 nh2 nh3 datah

[Parameters] 01h≤nh1≤15h

nh2: 00h (fixed)

nh3: 01h (fixed)

00h≤datah≤FFh

[Description]

Specifies the non-printed text string.

nh1+(nh2*256): Length of the text string (0 to 20) + 1

data:

Text string (The maximum number of characters that can be set is 20 characters

(bytes).)

This command is a static command.

[Remarks]

Invalid if more than 20 characters are specified

[Example]

To specify the non-printed text string as “ABCD”:

Since the text string contains four characters, nh1=05h and nh2=00h, and then the

command will be as follows.

ESC i X a 2 05h 00h 01h A B C D

(1Bh 69h 58h 61h 32h 05h 00h 01h 41h 42h 43h 44h)