Error condition reporting, Table 3–7 emu status displays (continued), Error condition reporting –18 – HP Array Controller HSG V8.7 Software User Manual

Page 74: Table 3–7 emu status displays –18, Environmental monitoring unit

Advertising
background image

Environmental Monitoring Unit

3–18 UltraSCSI RAID Enclosure

Error Condition Reporting

EMU status LEDs identify system (enclosure) status, power status,
temperature status, blowers status, and error conditions. During
normal operations, only the power LED is O

N

. Refer to Figure 3–5 as

necessary to recall EMU status LED names and locations. Figures
contained in Table 3–7 describe:

EMU status LED display appearance

Enclosure status associated with each display

A probable cause for the detected error condition

Action recommended to correct the problem

Note

Presenting all possible LED display combinations is not
practical in this document. Therefore, Table 3–7 lists only a
representative sampling of the displays possible.

Table 3–7

EMU Status Displays

EMU Status

EMU LED Display

Operational Enclosure

The subsystem is fully operational.

The power supplies and blowers are
functioning properly. The EMU intake
and backplane exhaust air temperatures
are within user-specified limits.

1

2

3

4

5

6

7

8

CXO5778A