Ftp interface (single card), Upgrade firmware using ftp, Specify binary mode: binary – HP Tape Library Interface Manager Software User Manual
Page 75: Ftp interface (single card) 75, Upgrade firmware using ftp 75

Chapter 3
Management Operations 75
Chapter 3
FTP Interface (Single Card)
The IM can use FTP to update the firmware on a single card.
Upgrade Firmware Using FTP
To upgrade the firmware using FTP, do the following:
1. Connect the IM to the Ethernet network used by your computer.
2. Start your FTP program using the IM’s IP address:
ftp <IP address>
Note
If you do not know the IP address of the IM (or need to change
the IP address), connect to the IM using the RS-232 (serial)
connection. Current information can be seen and changed from
the Network Configuration menu.
3. Use
[download] as the user name and the same password that you used
for Telnet and Web access.
Note
To change the password, see
4. Specify binary mode:
Binary
5. Specify the firmware’s path and filename with the
[put]
command:
put <filename> /firmware/chunker/<slot>
<slot> is a number from 1 through 12 that represents the slot number of the
card receiving the new firmware. The slot number represents the card’s
position in the interface manger.
— Slot number 1 should contain the RMC (disregard the card type number
2 on the card, the correct slot number is 1).
— Slot number 2 should contain the Controller card (disregard the card
type number 3 on the card, the correct slot number is 2).
— Slots numbered 3 through 12 should contain the interface cards.
The file will transfer and the card in the assigned slot will reboot. The card will