Fc-64 director (mcdata) switch, Fc-64 director (mcdata) switch 96 – HP Tape Library Interface Manager Software User Manual
Page 96
 
96 SAN Environments
Chapter 4
Figure 28
Fibre Channel Switch Configuration
FC-64 Director (McData) Switch
Use the default mode for the FC-64 switch in SAN backup configurations.
You must make the following changes to the default configuration:
1. The FC-64 Fibre Channel switch does not support public or private loop 
connections. All devices must use login as N_port only.
2. Set the Interface Manager Hard ALPA setting to [NO] and the Fibre
Channel port mode to [N_port].
3. Set the addressing to [Soft] on internal Fibre Channel cards.
switch59:admin> version 
Kernel: 5.3.1 
Fabric OS: v2.1.9f 
Made on: Mon Dec 4 14.37.39 PST 2000 
Flash: Mon Dec 4 14.38.10 PST 2000 
BootProm: Thu Jun 17 15:20:39 PDT 1999 
switch59:admin> 
switch59:admin> switchshow 
switchName: switch59 
switchType: 3.4 
switchState: Online 
switchRole: Principal 
switchDomain: 2 
switchId: fffcO2 
switchWwn: 10:00:00:60.169.20.24:04 
part 0: sw Online F-Port 50:06:0b:00:00:00:79:dO 
port 1: sw Online F-Port 50:06:0b:00:00:06:d4:96 
port 2: sw Online F-Port 50:06:0b:00:00:06:d3:dc 
port 3: -- No-Module 
port 4: -- No-Module 
port 5: -- No-Module 
port 6: id Online F-Port 10:00:00:e0:02:21:b9:a2 
port 7: -- No-Module 
switch59:admin> 
switch59:admin> qlShow 
Switch is not in Quick Loop mode. 
switch59:admin> 
switch59:admin> zoneShow 
Defined configuration: 
 no configuration defined 
 
Effective configuration, 
 no configuration in effect 
 
switch59:admin>