Chapter 5

Reconstructing and Rebuilding Drives

106

2. Choose Rebuild from the Management menu. A device selection window

is displayed showing the devices connected to the current adapter. The
failed drives have FAIL indicators.

3. Use the arrow keys to highlight the first physical drive to be rebuilt then

press the Spacebar to select it.

4. Use the arrow keys and Spacebar to select any additional physical drives to

be rebuild.

5. Press F10 and type Yes at the confirmation prompt. The indicators for the

selected drives change to REBLD.

6. When the rebuild is complete, press any key to continue. Press Esc to

return to the Management menu.

Manual Rebuild from HP NetRAID Express Tools (under any NOS)

1. Log off all users, close all applications, and power down the HP NetServer.

2. Restart the server. Look for the following prompt during startup:

Option: Experienced users may press <Ctrl> <M> for
HP NetRAID Express Tools now.
Firmware Initializing

3. Press <Ctrl> <M>. When the system stops scanning, HP NetRAID

Express Tools starts.

4. Choose Rebuild from the Tools Management menu.

5. Use the arrow keys to highlight one or more physical drives to be rebuilt.

6. Use the Spacebar to select (or deselect) the drive to be rebuilt.

7. Press F10 to start the rebuilding process.