HP NetRAID 1Si Controller User Manual

Page 33

Advertising
background image

Chapter 2

HP NetRAID Assistant

27

Define your physical arrays.

Assign dedicated hot spares, if desired.

Define logical drives.

Preview configuration and save it to NVRAM (non-volatile memory).

Save the configuration to a binary file.

Print the configuration.

Configure any other adapters.

Initialize logical drives.

Exit HP NetRAID Assistant.

Select the Adapter to Configure

Look in the Adapter box to see if the adapter you wish to configure is displayed. If
not, select it from the pull-down list.

Clear Configuration (if necessary)

If you want to set up a brand-new configuration, you should clear the existing
configuration.

To clear the existing configuration:

1. Select the Configuration menu.

2. Choose Clear Configuration.

3. Click OK.

Check Rebuild Rate

During a rebuild, the contents of a complete physical drive is rewritten. Normal
operations can go on during a rebuild, but performance may be degraded. The
Rebuild Rate controls the rate at which a rebuild is done. A high Rebuild Rate
(over 50%) speeds up the rebuild, but slows system performance. A low Rebuild
Rate (under 50%) slows the rebuild process, but speeds up system performance.
The default setting for the Rebuild Rate is 50%.

To check the Rebuild Rate from the HP NetRAID Assistant window:

1. Select the adapter for which you want to check the Rebuild Rate.

2. Select Rebuild Rate from the Adapter menu.