C configuring arrays and logical drives – HP NetRAID 1Si Controller User Manual

Page 63

Advertising
background image

Chapter 3

HP NetRAID Config

57

4. When the consistency check is finished, press any key to clear the progress

display and press Esc to return to the Management menu.

NOTE

Check Consistency might fail if the firmware could not
complete parity and data writes due to a power failure or a
system hang, or if the logical drive degraded or failed when a
physical drives went offline.

Advanced Menu

Reconstruct Logical Drive

Use this option if you want to add a physical drive or change a RAID level. For
complete information on adding a physical drive, see Chapter 6, "Capacity
Expansion," in this guide. For information on changing RAID levels, see
"Changing the RAID Level of a Logical Drive" in part F of this chapter,
"Changing Logical Drives Currently in Use."

C Configuring Arrays and Logical Drives

Each configuration method requires a different level of user input. However, the
general flow of operations for array and logical drive configuration is outlined
below.

1. Choose a configuration method.

2. Designate hot spares (optional).

3. Configure the logical drives.

4. Initialize the logical drives.

Configuration Methods

HP NetRAID Config has five configuration options:

Auto Configuration examines the physical drives and automatically
configures them into arrays and logical drives. It does not disturb existing
configuration information. For instructions on using this selection, see
"Using Auto Configuration" in this chapter.

Easy Configuration lets you create arrays, hot spares, and logical drives,
but it does not modify an existing configuration. This selection does not
permit array spanning. If there are already logical drives configured, their

Advertising
This manual is related to the following products: