Chapter 3

HP NetRAID Config

52

Adapter

Choose Adapter from the Objects menu to select an integrated HP NetRAID
controller or HP NetRAID Series adapter (if your HP NetServer has more than
one) and to modify parameters.

Clear Configuration: Erases the current configuration from the adapter’s
nonvolatile memory.

View Adapter Performance: Displays the selected adapter's read/write
performance.

Power Fail Safeguard: Lets you enable or disable the Power Fail
Safeguard feature. This feature allows users to protect a disk array during
the reconstruction process should a power failure occur. If Power Fail
Safeguard is enabled, reconstruction takes longer, but your data is
protected against loss. The default setting is Enabled.

For complete information about the Power Fail Safeguard feature, see
"Power Fail Safeguard Feature" in Chapter 5 of this guide.

Disk Spin-Up Timings: Sets the method and timing for spinning up the
hard disk drives in the HP NetServer. The default setting is Automatic.

Alarm Control: For HP NetRAID Series adapters there are two onboard
tone generator settings, described below. (This option is not available for
integrated HP NetRAID controllers.)

Enable/Disable Alarm: Choose this option to enable or disable the
onboard tone generator. The default setting is Enabled.

Silence Alarm: This setting stops the alarm when it goes off.

For complete information, see Chapter 8, "Alarm Control and Audible
Warnings."

View/Update Parameters: Displays the properties of the selected adapter:
Rebuild Rate (default is 50%), Firmware Version, BIOS Version, DRAM
Size, and logical drive properties. The only parameter you can change is
the Rebuild Rate. (For complete information on the Rebuild Rate, see
"Changing the Rebuild Rate" in Chapter 5 in this guide.)