Chapter 3

HP NetRAID Config

70

Changing the RAID Level of a Logical Drive

To make RAID level changes, refer to the valid RAID level changes listed in
Table 3-1 before altering a logical drive.

NOTE

You cannot change the RAID level of any logical drive that
spans arrays (RAID levels 10, 30, or 50).

Table 3-1. Valid HP NetRAID Configuration Changes

Existing RAID
Configuration

Valid RAID

Configuration Change

Configuration Event

RAID 3 or RAID 5 Optimal

RAID 3 or RAID 5 Optimal

Expanding capacity

RAID 3 or RAID 5 Optimal

RAID 0

Stopping parity

RAID 3 or RAID 5 Optimal

RAID 0

Deleting a drive, or
adding drives

RAID 3 or RAID 5 Optimal
or Degraded

RAID 0

Reconfiguring as
Optimal RAID 0

RAID 1 Optimal

RAID 3 or RAID 5 Optimal

Adding drives

RAID 1 Optimal

RAID 0

Deleting a drive

RAID 1 Degraded

RAID 0

Reconfiguring as
Optimal RAID 0

RAID 0 Optimal

RAID 3 or RAID 5 Optimal

Adding drives

RAID 0 Optimal (with one
drive)

RAID 1 Optimal

Adding a drive

RAID 0 Optimal

RAID 0

Adding drives

To change the RAID level of a logical drive that is currently in use, the logical
drive must be reconstructed. Follow these steps:

1. Choose Advanced Menu from the HP NetRAID Config Management

menu.

2. Select Reconstruct Logical Drive.

3. Select the logical drive to be changed. A Reconstruct window is displayed.

4. Press Enter to see the Reconstruct menu.

5. Select RAID level.

6. Choose the new RAID level.

Advertising