Causes and solutions

Problem

3.

Reboot the host server or run a command that causes the system to recognize the device.

4.

Start the monitoring application on the host and check whether the host has access to pair
volumes (see

“Fast Snap pair status” (page 15)

).

Cause: A port may go offline because access to a volume on another port has been rejected.

The host computer attempts to
access the port and an error
occurs.

Solutions:

Wait until the process has completed and then retry the task.

If a host application is installed to monitor the volume, stop the application.

Causes:

RWC times out frequently.

RWC cannot respond to the SVP because the load is too heavy.

The time-out period is not an adequate length.

Solutions:

Wait until the process has completed and then retry the task.

Verify the values for RWC’s RMI time-out period.

For more information about how to set RMI time-out period, see the HP XP7 Remote Web Console
User Guide
.

FS processing may be in progress. The update will complete sometime after the FS processing
finishes.

The pair information in Local
Replication window is not
updated. The date and time in
Last Updated is not updated.

The copy processing is running.

After a host completes a write
operation, the used pool

Solution:

capacity shown in the

Wait until the copy processing is completed. The used pool capacity shown in the Summary
section of the Pools window and in the list in the Primary Volumes tab of the selected pool
matches.

Summary section of the Pools
window and in the list in the
Primary Volumes tab of the
selected pool do not match.

For more information about viewing the used pool capacity in this section and on this tab, see

“Monitoring pool information” (page 111)

.

You are attempting to create a blocked and suspended (“PSUE” status) pair.

You cannot resynchronize a
suspended FS pair (“PSUE”
status).

Solution:

1.

Delete the FS pairs related to the P-VOL (see

“Deleting Fast Snap pairs” (page 85)

).

2.

Create the FS pair (see

“Creating Fast Snap pairs” (page 64)

).

If the solutions in this table do not work, or if your problem is not included in this table, contact HP
Technical Support.

Workflow for completing SIMs related to cache management devices

The following SIM (service information message) is issued if the number of the remaining cache
management devices falls below 4,096:

Reference code 670000

For more information about SIM reference codes, contact HP Technical Support.

You can view SIMs that occur in the storage system in an RWC window.

For more information about checking alerts and the details of a SIM, see the HP XP7 Remote Web
Console User Guide
.

Use the following workflow to complete the warning SIMs related to cache management devices:

1.

Confirm that the number of the remaining cache management devices is at least 4,096 (see

“Calculating the number of the remaining cache management devices” (page 141)

).

2.

Remove the unneeded V-VOLs.

140 Troubleshooting