Cause of error

RAID Manager command

SSB2

You cannot create the FS pair because you have specified a THP V-VOL in the
initialization process as the FS P-VOL.

paircreate

97A4

The command ended abnormally because you specified a volume that was
undergoing online data migration as the FS P-VOL.

All commands

97A5

The command ended abnormally because you specified a volume that was
undergoing online data migration as the FS S-VOL.

All commands

97A6

You cannot create the pair and use the specified consistency group because
you have you have reached the maximum number of the consistency groups that
can be created.

paircreate

97B4

You cannot create the FS pair for the specified P-VOL because the maximum
number of snapshot ID (MU number) was used.

paircreate

97B5

You cannot create the FS pair because of one of the following reasons:

paircreate

97B6

You were in the process of creating a new snapshot group but you reached
the maximum number of snapshot groups that can be created.

You have specified a snapshot group which has reached the maximum number
of pairs allowed in a group.

You cannot create the FS pair because the THP pool is being initialized.

paircreate

97B7

The command ended abnormally because the status of the pairs using the P-VOL
you specified is suspended (“PSUE” status).

paircreate, pairsplit,
pairresync, pairresync
-restore

97B9

You cannot create the FS pair from the consistency group to which the specified
snapshot group belongs because of one of the following reasons:

paircreate

97BF

BC is using the specified consistency group.

You have reached the maximum number of pairs that can be created for a
consistency group.

A pair that uses the same P-VOL exists already in the specified snapshot
group.

The command ended abnormally because you specified an MU number outside
the allowable range.

All commands

97C2

The command ended abnormally because of one of the following reasons:

All commands

97C4

You have specified a pool that is not an FS pool.

You have specified a pool that does not exist.

The command ended abnormally because FS is not installed.

paircreate, pairsplit,
pairresync, or pairresync
-restore

97C6

You cannot create the FS pair because the capacity of cache management
devices is insufficient.

paircreate

97C7

You cannot create the FS pair because the capacity of the volume you specified
as the P-VOL or the S-VOL of the FS pair is more than the supported size (4TB).

paircreate

97C8

The command ended abnormally because you specified a pool that is not an
FS pool.

All commands

97CB

You cannot create the FS pair because an FS group is already using the CG
number you specified.

paircreate

97CF

The command ended abnormally because you are in the process of turning off
the power.

All commands

97D4

You cannot run the command because even though the specified serial number
matches the virtual storage machine, the physical storage system's serial number

All commands

97D5

that corresponds with the virtual storage machine's serial number does not match

154 RAID Manager command reference