Confirm window, Bc/fs system options table – HP XP7 Storage User Manual

Page 193

Advertising
background image

Description

Item

FC Slower Copy1 (FC Z or FCSE only): Reduces the multiplicity of background
copy into half.

FC Slower Copy 2 (FC Z or FCSE only): Reduces the multiplicity of background
copy into quarter.

FC Ext. Slower Copy1: Inhibits background copy and improves host I/O
response when the operating ratio of the MP blade (FC Z or FCSE S-VOL or
T-VOL is allocated) exceeds 65%.

FC Ext. Slower Copy2: Inhibits background copy and improves host I/O
response when the operating ratio of the MP blade (FC Z or FCSE S-VOL or
T-VOL is allocated) exceeds 50%.

Copy Pace Ext. Slower1

Copy Pace Ext. Slower2

Copy Pace Ext. None

Reducing the copy volume in the “DUPLEX” status curbs the influence to the I/O
performance of the host server. This item is available to all pairs in “DUPLEX”
status. The I/O performance of the host server is improved in order of Copy
Pace Ext. Slower1, Copy Pace Ext. Slower2, and Copy Pace Ext. None.

Shows whether the option is currently enabled or disabled.

Status

Click to enable the selected option.

Enable button

Click to disables the option.

Disable button

Confirm window

This window is the second window of the Edit Local Replica Options wizard.
The following image shows this window of the Edit Local Replica Options wizard.

BC/FS System Options table

The following table lists the items in the BC/FS System Options table in the Confirm window of the
Edit Local Replica Options wizard.

Description

Item

Options that can be changed.

System Option

Shows whether the option is currently enabled or disabled.

Status

Edit Local Replica Options wizard

193

Advertising
This manual is related to the following products: