69 Cache Batteries Low, Recharging
Type: Informational
Description: The batteries on the cache module are low; the storage system is
recharging the batteries.
Action: None
70 Cache Disabled No Configuration
Type: Informational
Description: The controller has disabled the cache because the cache is not
configured.
Action: Use ACU to configure the cache.
71 System Halted for Cache Error
Type: Error
Description: The user has chosen to address a critical cache error condition. This
message always appears after message 72 ("72 Cache Error <n> Ignore>? <=NO
>=YES" on page
). Message 72 is removed from the LCD after it has
accepted user input.
Action:
• Select the NO option to halt the controller and solve the problem.
• Select the YES option to erase the cache data. Operation of the controller
continues normally.
Error 1.1 and 1.2: Only one cache board is in the controller, but the controller
was configured with a second cache board that is missing (dual cache module
configuration).