102 volume #<n> state interim recovery, 103 volume #<n> state rebuilding, 104 volume #<n> state disabled – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 112

112
HP StorageWorks MSA500 G2 Storage System User Guide
102 Volume #<n> State Interim Recovery
Type: Informational
Description: The controller failed one or more of the physical drives that
constitute the configured volume. No data loss has occurred because fault
tolerance is allowing data recovery.
Action: Replace the failed drive or drives as soon as possible ("Recognizing hard
drive failure" on page
103 Volume #<n> State Rebuilding
Type: Informational
Description: The configured volume is rebuilding data on a physical drive that
replaced a previously failed drive.
Action: None
104 Volume #<n> State Disabled
Type: Error
Description: The controller disabled the configured volume because too many
drives that constitute the volume are missing.
Action:
1. Power down the storage system (on page
2. Power down all attached storage enclosures.
3. Remove and reinstall all SCSI drives, and be sure that they seat fully in their
bays.
4. Check for proper connections on the cables to and from the MSA500 G2
storage system.
5. Power up the attached storage enclosures.