413 storage box #<n> emu version <version, 500 initializing pci subsystem, 501 pci subsystem hardware failure – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 129: 502 pci bridge asic self test failure

Troubleshooting
129
413 Storage Box #<n> EMU Version <version>
Type: Informational
Description: Displays the version of the firmware running on the I/O EMU. This
display only applies to the internal I/O EMU of the storage system The controller
does not display versions for externally connected storage boxes.
Action: None
500 Initializing PCI Subsystem
Type: Informational
Description: The controller PCI subsystem is initializing as part of the power-up
sequence.
Action: None
501 PCI Subsystem Hardware Failure
Type: Error
Description: The controller PCI subsystem encountered a critical error during
the power-up sequence.
Action:
1. Remove the failed controller.
2. Wait 10 seconds.
3. Reinstall the controller, and be sure that it seats fully in the chassis.
If this action does not solve the problem, contact HP support.
502 PCI Bridge ASIC Self Test Failure
Type: Error