407 Storage Box #<n> Overheated
Type: Error
Description: The temperature sensor in the specified storage system indicates
that the temperature exceeded the normal operating range.
Action:
1. Avoid hardware failure. Power down the storage system (on page
2. Be sure that all MSA500 G2 storage system fans are operating.
3. Replace any failed fans.
4. Be sure that all bays are populated with components or blanks.
If this action does not solve the problem, contact HP support.
408 Storage Box #<n> Power Supply OK
Type: Informational
Description: The specified storage system indicates that one of its previously
failed power supplies is now operating normally.
Action: None
409 Storage Box #<n> Power Supply Failed
Type: Error
Description: The specified storage system indicates that one of its power
supplies has failed.
Action:
1. Check all power supplies for damage.
2. Replace any failed power supplies.