204 array controller disabled, 205 array controller restarting, 300 recovery rom autoflash started – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 120

120
HP StorageWorks MSA500 G2 Storage System User Guide
4. Be sure that all bays are populated with components or blanks.
If this action does not solve the problem, contact HP support.
204 Array Controller Disabled
Type: Error
Description: The controller is disabled because of a redundancy failure.
Action:
1. Remove the failed controller.
2. Wait 10 seconds.
3. Reinstall the controller, and be sure that it seats fully in the chassis.
If this action does not solve the problem, contact HP support.
205 Array Controller Restarting
Type: Informational
Description: The controller has completed Controller Firmware Auto Cloning
and is restarting automatically.
Action: None
300 Recovery ROM Autoflash Started
Type: Informational
Description: Indicates that the controller detected that the backup recovery ROM
image of the firmware is invalid and is copying the current active firmware
image into the backup recovery ROM.
Action: None