201 array controller temperature ok, 202 array controller overheating, 203 array controller overheated – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 119

Troubleshooting
119
201 Array Controller Temperature OK
Type: Informational
Description: The controller temperature is within the normal operating range.
This message appears when the temperature problem no longer exists, and it
follows message 202 and/or message 203.
Action: None
202 Array Controller Overheating
Type: Error
Description: The temperature sensor on the controller indicates the controller is
exceeding the normal operating range.
Action:
1. Be sure that all MSA500 G2 storage system fans are operating.
2. Replace any failed fans.
3. Be sure that all bays are populated with components or blanks.
If this action does not solve the problem, contact HP support.
203 Array Controller Overheated
Type: Error
Description: The temperature sensor on the controller indicates the controller
exceeded the normal operating range.
Action:
1. Avoid hardware failure. Power down the storage system (on page
2. Be sure that all MSA500 G2 storage system fans are operating.
3. Replace any failed fans.