513 uncorrected ecc memory error seen, 518 <name> connection lost, 519 <name> connection restored – HP StorageWorks 500 G2 Modular Smart Array User Manual

Page 130

Advertising
background image

130

HP StorageWorks MSA500 G2 Storage System User Guide

Description: The controller PCI bridge ASIC has encountered a critical error
during the power-up sequence.

Action:

1. Remove the failed controller.

2. Wait 10 seconds.

3. Reinstall the controller, and be sure that it seats fully in the chassis.

If this action does not solve the problem, contact HP support.

513 Uncorrected ECC Memory Error Seen

Type: Error

Description: The controller has detected an uncorrectable error in the ECC
memory on the memory cache board.

Action: Remove the failed controller. Replace the cache module DIMM.

518 <name> Connection Lost

Type: Error

Description: The named connection has been lost.

Action: Check SCSI connections to the server. Also, the controller may have a
failed SCSI controller chip.

519 <name> Connection Restored

Type: Error

Description: The named connection has been restored.

Action: None

Advertising