80 replacement drive found box #<n> bay <n, 81 smart drive alert box #<n>, bay <n, 82 drive hot added box #<n>, bay <n – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 108

108
HP StorageWorks MSA500 G2 Storage System User Guide
3. Reinstall both controllers, and be sure that they seat fully in the chassis.
If this action does not solve the problem, contact HP support.
80 Replacement Drive Found Box #<n> Bay <n>
Type: Informational
Description: A SCSI drive that was previously missing or failed has been
replaced with a working SCSI drive.
Action: None
81 Smart Drive Alert Box #<n>, Bay <n>
Type: Informational
Description: A SCSI drive may be close to failing. The prefailure condition was
determined either by the drive firmware using SMART technology or by the
controller using monitor and performance testing.
Action: Replace the failed drive or drives as soon as possible ("Recognizing hard
drive failure" on page
82 Drive Hot Added Box #<n>, Bay <n>
Type: Informational
Description: A SCSI drive has been added to the MSA500 G2 storage system.
Action: None