30 i2c read failure <i2c device name, 31 i2c write failure <i2c device name, 32 chassis nvram contents corrupted – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 93

Troubleshooting
93
2. Examine all attached SCSI devices.
3. Remove any SE devices found and replace them with LVD devices.
30 I2C Read Failure <I2C device name>
Type: Error
Description: Read access has failed on an internal device on an I2C hardware
bus. Certain I2C devices are considered critical and result in a failure of the
controller while others may result in some loss of functionality (such as lost
display messages).
Action: Replace the device. If this action does not solve the problem, contact HP
support.
31 I2C Write Failure <I2C device name>
Type: Error
Description: Write access has failed on an internal device on an I2C hardware
bus. Certain I2C devices are considered critical and result in a failure of the
controller while others may result in some loss of functionality (such as lost
display messages).
Action: Replace the device. If this action does not solve the problem, contact HP
support.
32 Chassis NVRAM Contents Corrupted
Type: Error
Description: NVRAM is corrupt. The storage system cannot continue to operate.
Action: Contact HP support.