124 Spares Cleared

Type: Informational

Description: A set of volumes have been migrated from one controller to a
different controller that already contains configured volumes. The migrated
volumes have spares defined for them that conflict with the existing
configuration. The defined spares have been deleted to allow the migration to
proceed.

Action: Run ACU to reassign spare drives as needed.

125 Access Control Conflict Detected

Type: Error

Description: A set of volumes have been migrated from one controller to a
different controller that already contains configured volumes. The migrated
volumes have access controls defined for them that conflict with the existing
configuration. The access controls have been modified to allow the migration to
proceed.

Action: Run ACU to check the new access controls and modify them, if needed.

126 Access Control Resources Exceeded

Type: Error

Description: A set of volumes have been migrated from one controller to a
different controller that already contains configured volumes. The migrated
volumes have access controls defined for them that conflict with the existing
configuration. The access controls have been modified to allow the migration to
proceed.

Action: Run ACU to check the new access controls and modify them, if needed.