304 rom cloning done, 305 rom cloning failed, 306 firmware flash started – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 122

122
HP StorageWorks MSA500 G2 Storage System User Guide
304 ROM Cloning Done
Type: Informational
Description: Indicates that the two controllers in an MSA500 G2 storage system
completed the Controller Firmware Auto Cloning process.
Action: Refer to Controller Firmware Auto Cloning (on page
305 ROM Cloning Failed
Type: Error
Description: Indicates that the two controllers in an MSA500 G2 storage system
failed the Controller Firmware Auto Cloning process.
Action:
1. Remove the failed controller.
2. Wait 10 seconds.
3. Reinstall the controller, and be sure that it seats fully in the chassis.
The controller reattempts the Controller Firmware Auto Cloning process again.
If this action does not solve the problem, contact HP support.
306 Firmware Flash Started
Type: Informational
Description: Indicates that the controller in an MSA500 G2 storage system is
flashing the firmware.
Action: Do not power down the storage system until the process is complete. The
process could take up to 5 minutes.