HP StorageWorks 500 G2 Modular Smart Array User Manual
HP Storage
Advertising
Table of contents
Document Outline
- HP StorageWorks Modular Smart Array 500 Generation 2 Storage System User Guide
- Notice
- Contents
- Component identification
- Operations
- Setup
- Rack planning resources
- Optimum environment
- Rack warnings
- Shipping contents
- Rack mounting hardware kit contents
- Converting rails for round-hole racks
- Installing a storage system into the rack
- Installing hardware options
- Installing servers
- Choosing a configuration
- Cabling the storage system
- Updating firmware
- Hardware options installation
- Configuration and utilities
- Cluster installation and configuration
- Troubleshooting
- When the storage system does not start
- Diagnostic steps
- Recognizing hard drive failure
- Factors to consider before replacing hard drives
- Automatic data recovery (rebuild)
- Drive failure in a NetWare environment
- Display messages
- Box numbering
- 00 Array Controller Firmware Ver <version>
- 01 HP MSA500-G2 Startup Complete
- 02 Enable Volume <n>? '<'=NO, '>'=YES
- 03 Critical Lock-Up Detected. Code=<n>h
- 04 Enable Volumes ? '<'=NO, '>'=YES
- 05 System Name: <name>
- 06 Restarting System
- 07 Clone Firmware? '<'=NO, '>'=YES
- 08 Firmware Flash Failed
- 20 Initializing SCSI Subsystem
- 21 Scanning for SCSI Devices
- 22 Initializing SCSI Devices
- 24 Bad SCSI Bus Mode Non-LVD Device Found
- 30 I2C Read Failure <I2C device name>
- 31 I2C Write Failure <I2C device name>
- 32 Chassis NVRAM Contents Corrupted
- 40 Begin Redundancy Support
- 41 Redundancy Active Active Controller
- 42 Redundancy Active Standby Controller
- 43 Redundancy Failed Hardware Failure
- 44 Redundancy Failed Mismatch Hardware
- 45 Redundancy Failed Mismatch Hardware
- 47 Redundancy Failed Cache Size Mismatch
- 48 Redundancy Halted Firmware Cloned
- 49 Redundancy Failed Firmware Lockup
- 50 Redundancy Failed Out of Memory
- 51 Redundancy Failed I/O Request Error
- 52 Redundancy Failed PCI Bus Error
- 53 Redundancy Failed No Second Controller
- 54 Redundancy Failed Cache DIMMs Mismatch
- 60 No Cache Module Found
- 61 Dual Cache Module Size Mismatch
- 62 Cache Module #<n> <n>MB
- 63 Valid Cache Data Found at Power-Up
- 64 Cache Data Lost Battery Dead
- 65 Cache Hardware Enabled
- 66 Cache Hardware Failed and Disabled
- 67 Cache Hardware Temporarily Disabled
- 68 Obsolete Cache Data Deleted
- 69 Cache Batteries Low, Recharging
- 70 Cache Disabled No Configuration
- 71 System Halted for Cache Error
- 72 Cache Error <n> Ignore>? <=NO >=YES
- 73 Cache Hardware Batteries Missing
- 80 Replacement Drive Found Box #<n> Bay <n>
- 81 Smart Drive Alert Box #<n>, Bay <n>
- 82 Drive Hot Added Box #<n>, Bay <n>
- 83 Drive Hot Removed Box #<n>, Bay <n>
- 84 Drive Failure Box #<n>, Bay <n>
- 85 Bad Drive Failure Box #<n>, Bay <n>
- 86 Drive Position Change Detected
- 87 Drive Position Change Invalid
- 89 Invalid Volume Addition
- 90 RIS Version Exceeded
- 100 Volume #<n> State OK
- 101 Volume #<n> State Failed
- 102 Volume #<n> State Interim Recovery
- 103 Volume #<n> State Rebuilding
- 104 Volume #<n> State Disabled
- 105 Volume #<n> State Expansion Active
- 106 Volume #<n> State Waiting to Rebuild
- 107 Volume #<n> State Waiting to Expand
- 108 Volume #<n> State Missing Drives
- 109 Volume #<n> State Wrong Drive Replaced
- 110 Volume #<n> Expansion Disabled
- 111 Volume #<n> Initializing Parity
- 112 Volume #<n> Rebuild Failure
- 113 Volume #<n> Expansion Failure
- 114 Volume #<n> State Deleted
- 120 Configured Volumes #<n>
- 121 No Volumes Detected
- 122 New Volumes Detected
- 123 Too Many Volumes Detected
- 124 Spares Cleared
- 125 Access Control Conflict Detected
- 126 Access Control Resources Exceeded
- 201 Array Controller Temperature OK
- 202 Array Controller Overheating
- 203 Array Controller Overheated
- 204 Array Controller Disabled
- 205 Array Controller Restarting
- 300 Recovery ROM Autoflash Started
- 301 Recovery ROM Autoflash Done
- 302 Recovery ROM Autoflash Failed
- 303 ROM Cloning Started
- 304 ROM Cloning Done
- 305 ROM Cloning Failed
- 306 Firmware Flash Started
- 307 Firmware Flash Done
- 308 Firmware Flash Failed
- 309 EMU Flash Started
- 310 EMU Flash Done
- 311 EMU Flash Failed
- 400 Storage Box #<n> Fan OK
- 401 Storage Box #<n> Fan Failed
- 402 Storage Box #<n> Fan Degraded
- 403 Storage Box #<n> Fan Hot Inserted
- 404 Storage Box #<n> Fan Hot Removed
- 405 Storage Box #<n> Temperature OK
- 406 Storage Box #<n> Overheating
- 407 Storage Box #<n> Overheated
- 408 Storage Box #<n> Power Supply OK
- 409 Storage Box #<n> Power Supply Failed
- 410 Storage Box #<n> Power Supply Added
- 411 Storage Box #<n> Power Supply Removed
- 412 Storage Box #<n> EMU Not Responding
- 413 Storage Box #<n> EMU Version <version>
- 500 Initializing PCI Subsystem
- 501 PCI Subsystem Hardware Failure
- 502 PCI Bridge ASIC Self Test Failure
- 513 Uncorrected ECC Memory Error Seen
- 518 <name> Connection Lost
- 519 <name> Connection Restored
- 520 Unknown I/O Module Detected
- 521 ULTRA 3 I/O Module Detected
- Regulatory compliance notices
- Regulatory compliance identification numbers
- Federal Communications Commission notice
- Declaration of conformity for products marked with the FCC logo, United States only
- Cables
- Modifications
- European Union regulatory notice
- Canadian notice (Avis Canadien)
- Japanese notice
- BSMI notice
- Korean notice A&B
- Battery replacement notice
- Taiwan battery recycling notice
- Power cord statement for Japan
- Electrostatic discharge
- Specifications
- Technical support
- Acronyms and abbreviations
- Index