83 drive hot removed box #<n>, bay <n, 84 drive failure box #<n>, bay <n, 85 bad drive failure box #<n>, bay <n – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 109

Troubleshooting
109
83 Drive Hot Removed Box #<n>, Bay <n>
Type: Informational
Description: A SCSI drive has been removed from the MSA500 G2 storage
system.
Action: None
84 Drive Failure Box #<n>, Bay <n>
Type: Informational
Description: A SCSI drive in the MSA500 G2 storage system has failed. If the
drive was part of a configured volume, the state of the volume depends on the
fault tolerance used.
Action: Replace the failed drive or drives as soon as possible ("Recognizing hard
drive failure" on page
85 Bad Drive Failure Box #<n>, Bay <n>
Type: Error
Description: A SCSI drive has corrupt firmware. Continued use of this drive
could result in drive failure, decreased performance, or data loss.
Action: Do one of the following:
• Update the drive firmware ("Management Agents" on page
• Replace the failed drive or drives as soon as possible ("Recognizing hard
If this action does not solve the problem, contact HP support.