83 drive hot removed box #<n>, bay <n, 84 drive failure box #<n>, bay <n, 85 bad drive failure box #<n>, bay <n – HP StorageWorks 500 G2 Modular Smart Array User Manual

Page 109

Advertising
background image

Troubleshooting

109

83 Drive Hot Removed Box #<n>, Bay <n>

Type: Informational

Description: A SCSI drive has been removed from the MSA500 G2 storage
system.

Action: None

84 Drive Failure Box #<n>, Bay <n>

Type: Informational

Description: A SCSI drive in the MSA500 G2 storage system has failed. If the
drive was part of a configured volume, the state of the volume depends on the
fault tolerance used.

Action: Replace the failed drive or drives as soon as possible ("Recognizing hard
drive failure" on page

78

).

85 Bad Drive Failure Box #<n>, Bay <n>

Type: Error

Description: A SCSI drive has corrupt firmware. Continued use of this drive
could result in drive failure, decreased performance, or data loss.

Action: Do one of the following:

• Update the drive firmware ("Management Agents" on page

60

).

• Replace the failed drive or drives as soon as possible ("Recognizing hard

drive failure" on page

78

).

If this action does not solve the problem, contact HP support.

Advertising