307 firmware flash done, 308 firmware flash failed, 309 emu flash started – HP StorageWorks 500 G2 Modular Smart Array User Manual
Page 123

Troubleshooting
123
307 Firmware Flash Done
Type: Informational
Description: Indicates that the controller in an MSA500 G2 storage system
completed the firmware flash process.
Action: Power down the storage system (on page
308 Firmware Flash Failed
Type: Error
Description: Indicates that the controller in an MSA500 G2 storage system
failed the firmware flash process.
Action: Attempt the flash process again. If this action does not solve the
problem, contact HP support.
309 EMU Flash Started
Type: Informational
Description: Indicates that the I/O EMU in the MSA500 G2 storage system is
flashing the firmware.
Action: Do not power down the storage system until the process is complete. The
process could take up to 5 minutes. If this action does not solve the problem,
contact HP support.