Resolving truecopy for – HP StorageWorks XP Remote Web Console Software User Manual

Page 182

Advertising
background image

Table 54 Troubleshooting Suspended TrueCopy for Mainframe Pairs (continued)

Corrective Action

Description

Applies to

Suspend Type

the CGROUP/FREEZE
command.

CESTPAIR (MODE=RESYNC)
TSO command.

None. The MCU will
automatically resynchronize

The MCU suspended all
TrueCopy for Mainframe

R-VOL (TrueCopy for
Mainframe Asynchronous)

MCU P/S-OFF

these TrueCopy for

Asynchronous pairs due to
MCU power-off.

Mainframe Asynchronous
pairs during power-on.

Execute one of the following;

The amount of sidefile
exceeds the specified current

M-VOL, R-VOL

by Sidefile Overflow

Add cache memory,

pending update data rate,

Increase the number of
paths between MCU and
RCU,

and the RCU data is not
transferred within the
specified offloading timer.

Decrease the number of
Async pairs, or

Decrease the host I/Os.

“Resolving TrueCopy for Mainframe Async Suspension Conditions” (page 182)

provides

troubleshooting instructions for the TrueCopy for Mainframe Asynchronous suspension conditions
caused by the offloading timer async option, the group timeout options (copy pending and RCU
ready), and recordset errors. Hardware failures which affect the cache storage/shared memory
of the MCU or RCU may also cause the TrueCopy for Mainframe Asynchronous pairs to be
suspended.

Table 55 Resolving TrueCopy for Mainframe Async Suspension Conditions

Recovery procedure

SIM

Causes of Suspension

Classification

According to SIM, remove
the hardware blockade or
failure.

DB0x

DB1x

DB2x

Hardware redundancy has
been lost due to some
blockade condition. As a
result, MCU-RCU
communication, creating or

MCU/RCU hardware

182

Troubleshooting

Advertising