Example 4 CQUERY Output Example

************** PPRC REMOTE COPY CQUERY - VOLUME *********************
* (PRIMARY) (SECONDARY) *
* SSID CCA LSS SSID CCA LSS*
*DEVICE LEVEL STATE PATH STATUS SERIAL# SERIAL# *
*------ --------- ---------- ----------- --------- --------- *
* 2A10 PRIMARY.. PENDING... ACTIVE.. 4300 10 00 4300 11 00 *
* CRIT(NO)....... CGRPLB(NO). 00A7FS0V0000 000000099999*
* PATHS SAID DEST STATUS: DESCRIPTION *
* ----- --------- ------ ------------------- *
* 1 aabb ccdd 01 PATH ESTABLISHED... *
* ---- ---- 00 NO PATH............ *
* ---- ---- 00 NO PATH............ *
* ---- ---- 00 NO PATH............ *
* IF STATE = PENDING/SUSPEND: TRACKS OUT OF SYNC = 47277 *
* TRACKS ON VOLUME = 50085 *
* PERCENT OF COPY COMPLETE = 6% *
* SUBSYSTEM WWNN LIC LEVEL *
* ----------- ---------------- ----------- *
* PRIMARY.... 0000000000000000 3.8.05.0000 *
*********************************************************************

The CRIT field is not used for TrueCopy for Mainframe Asynchronous (NO is always indicated).
The PATHS, SAID, DEST, STATUS, and DESCRIPTION fields indicate the path status for this pair.
If you issue the CQUERY command to the pair with the PATH parameter, all paths that can be used
for this pair are displayed.
The TRUCKS OUT OF SYNC field indicates the number of trucks out of sync. The TRUCKS ON
VOLUME field indicates the total number of trucks that the paired volumes have. The PERCENT OF
COPY COMPLETE indicates the percentage of cylinders that have already been copied for pair
resynchronization.
The MCU serial number field is used to display the following TrueCopy for Mainframe Asynchronous
information:
For 2105 and 2107 controller emulation:

For 3990-3, -6, and -6E controller emulations: