Command device – HP StorageWorks XP Remote Web Console Software User Manual

Page 43

Advertising
background image

Table 15 SAID Values for the PATH LINK Parameter (= ports) (REAR CL2) (continued)

SAID

Port

Package

Location

SAID

Port

Package

Location

SAID

Port

Package

Location

SAID

Port

Package

Location

X'00D3'

CLE-D

X'00DB'

CLE-M

X'005F'

CL6-R

X'0057'

CL6-H

X'00F3'

CLG-D

X'00FB'

CLG-M

X'007F'

CL8-R

X'0077'

CL8-H

1

SAID values in

“SAID Values for the PATH LINK Parameter (= ports) (REAR CL2)” (page 42)

are different from the ones in

“SAID

Values for the LINK Parameters (=ports) of RMF PPRC Link-path Statistical Information (REAR CL2)” (page 48)

.

2

For the XP disk array, the name of the package location is 2L.

3

For the XP disk array, the name of the package location is 2E.

4

For the XP disk array, the name of the package location is 2K.

5

For the XP disk array, the name of the package location is 2F.

Command Device

To use Business Continuity Manager, you must set the command device for it separately from the
command device for an open system. The command device for Business Continuity Manager may
be set only from Business Continuity Manager. For information about Business Continuity Manager,
see the HP Business Continuity Manager Software User Guide.

You can also use the Remote Web Console to find the command device for Business Continuity
Manager. To find the command device, click File, and then Basic Information on the menu bar of
the Remote Web Console main window, and then click LDEV tab in the Basic Information Display
window. For detailed information on the Basic Information Display window, see the HP
XP24000/XP20000 Remote Web Console User's Guide
.

If you use XP12000/XP10000 Disk Array or XP1024/XP128 Disk array for MCU or RCU, only
the volumes whose CU: LDEV number is between 00: 00 to 3F: FF can be used as command
devices.

F/M = FB Message Output Control Option when Operating R-VOLs

When the suspension or the release operation is performed from Business Continuity Manager to
the R-VOL of TrueCopy for Mainframe or TrueCopy for Mainframe Asynchronous pair in the Duplex
status, the status of the M-VOL becomes Suspend and the F/M = FB message is output to the host
connected to MCU. You can control the output of this message by setting the system option mode
776.

However, even if the system option mode 776 is set, the F/M = FB message is output when the
pair status becomes Suspend due to the failure. Moreover, the F/M = FB message is not output
regardless of the setting of system option mode 776 if PPRC support by host = No is selected on
the CU Option dialog box.

Table 16 Whether to Output the F/M=FB Message when Operating R-VOLs

Settings

Cause of the

suspension of M VOL

The system option mode 776 is OFF

Cause of the suspension of M VOL

PPRC support by host
= No

PPRC support by host
= Yes

PPRC support by host
= No

PPRC support by host

= Yes

No

Yes

No

No

Suspended by the
suspension or the
release operation from
BCM to R VOLs

No

Yes

No

Yes

Suspended by failure

Business Continuity Manager Support

43

Advertising